Digital pressure transmitter with oil-free ceramic sensor for measurement in gases or liquids
Two chamber aluminum or stainless steel (316L) housing.
Process connections: Threads, flanges or hygienic connections
Process temperature: -40 to +150°C (-40 to +302°F)
Measuring ranges: -1/0 up to to +40bar (+1.5 to +600psi)
Accuracy: ±0.05%, "Platinum" ±0.025%
International explosion protection certificates, overfill prevention WHG, SIL, hygienic approvals, marine approvals
Best fit for vacuum applications and applications with corrosive and abrasive media
Process safety through membrane breakage detection
Overload-resistant high purity ceramic sensor (99.9% Al 2 O 3 )
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
Highest safety due to gastight feedthrough with capabilities up to SIL2/3, certified to IEC 61508
Available with mounted manifolds: always fit, always tested for leaks
Pressure measuring principle