Information
Information
Proven solution for standard applications in mining, minerals and metals
Thanks to the integrated wiper, the ultrasonic Turbimax CUS71D bed level sensor delivers reliable, continuous measurements in thickener applications.
Predefined calibration models and the calibration- and sensor-related data saved in the sensor make commissioning fast and easy.
The versatile Liquiline CM442 transmitter offers a user-friendly operating menu and advanced diagnostic functionalities with Hearbeat Technology. The weather protection cover CYY101 ensures easy readability of the Liquiline CM442 display at the measuring point.
The Flexdip CYH112 immersion assembly offers flexible adaptation options perfectly fitting to the thickener design and the measuring task.
Specifications
Smooth and robust measurements
Thanks to the integrated wiper, the ultrasonic Turbimax CUS71D bed level sensor delivers reliable, continuous measurements in thickener applications.
Simple commissioning
Predefined calibration models and the calibration- and sensor-related data saved in the sensor make commissioning fast and easy.
Comfortable operation
The versatile Liquiline CM442 transmitter offers a user-friendly operating menu and advanced diagnostic functionalities with Hearbeat Technology. The weather protection cover CYY101 ensures easy readability of the Liquiline CM442 display at the measuring point.
Optimal adaptation to your process requirements
The Flexdip CYH112 immersion assembly offers flexible adaptation options perfectly fitting to the thickener design and the measuring task.
Measuring principle
Ultrasonic sensor
Application
Continious interface measurement in sedimentation basins
Installation
Submerged sensor with fixed cable
Measuring range
0.3 to 10 m (1 to 32 ft)
Measuring principle
Ultrasonic return-time measurement
Material
Sensor: ABS and epoxy resin
Wiper: EPDM
Housing: Polyamide
Dimension
Diameter: 74 mm(2.9 inch)
Lenght standard sensor: 68 mm (2.7 inch)
Lenght wiper sensor: 135 mm (5.3 inch)
Process temperature
1 to 50 °C (34 to 122 °F)
Process pressure
Standard version: 0 to 6 bar (0 to 87 psi)
Version with wiper: 0 to 0.3 bar (0 to 4.4 psi)
Temperature sensor
-
Ex certification
None
Connection
Process connection: G1 and NPT 3/4"
Fixed cable 15 m
Ingress protection
IP68
Output / communication
Digital output for connection to Liquiline CM44x
Certificates, declarations and approvals
EAC
Measuring principle
Potentiometric
Application
Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic
Robust plastic housing
All non-ex applications
Design
2x Memosens input, 2 to 4x current output, Alarmrelay,
2x relay, SD card for software update and copy & paste of setup
Material
Housing base: PC-FR
Housing seal: EPDM
Dimension
237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature
-20 to 60 °C (0 to 140 °F)
Ingress protection
IP66 / IP67
Input
1 to 2x Memosens digital input
2x 0/4 to 20mA input optional
2x Digital input optional
Output / communication
2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals
EAC, cCSAus, MCERTS
Measuring principle
Sensor ORP / Redox
Application
Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic
Robust plastic housing
All non-ex applications
Design
2x Memosens input, 2 to 4x current output, Alarmrelay,
2x relay, SD card for software update and copy & paste of setup
Material
Housing base: PC-FR
Housing seal: EPDM
Dimension
237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature
-20 to 60 °C (0 to 140 °F)
Ingress protection
IP66 / IP67
Input
1 to 2x Memosens digital input
Output / communication
2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
Certificates, declarations and approvals
EAC, cCSAus, MCERTS
Measuring principle
Conductive
Application
Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic
Robust plastic housing
All non-ex applications
Design
2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material
Housing base: PC-FR
Housing seal: EPDM
Dimension
237 x 194 x 162 mm
9.33 x 7.64 x 6.38 inch
Process temperature
-20 to 60 °C (0 to 140 °F)
Ingress protection
IP66 / IP67
Input
1 to 2x Memosens digital input
Output / communication
2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
Certificates, declarations and approvals
EAC, cCSAus, MCERTS
Measuring principle
Amperometric oxygen measurement
Application
Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic
Robust plastic housing
All non-ex applications
Design
2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material
Housing base: PC-FR
Housing seal: EPDM
Dimension
237 x 194 x 162 mm
9.33 x 7.64 x 7.38 inch
Process temperature
-20 to 60 °C (0 to 140 °F)
Ingress protection
IP67
Input
1 to 2x Memosens digital input
Output / communication
2 to 4x 0/4...20 mA current outputs
Alarmrelay, 2x relay
Certificates, declarations and approvals
EAC, cCSAus, MCERTS
Measuring principle
Free chlorine
Application
Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic
Robust plastic housing
All non-ex applications
Design
2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material
Housing base: PC-FR
Housing seal: EPDM
Dimension
237 x 194 x 162 mm
9.33 x 7.64 x 7.38 inch
Process temperature
-20 to 60 °C (0 to 140 °F)
Input
1 to 2x Memosens digital input
Output / communication
2 to 4x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
Certificates, declarations and approvals
EAC, cCSAus, MCERTS
Measuring principle
Four beam alternating light
Application
Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic
Robust plastic housing
All non-ex applications
Design
2x Memosens input, 2 to 4x current output, Alarmrelay,
2x relay, SD card for software update and copy & paste of setup
Material
Housing base: PC-FR
Housing seal: EPDM
Dimension
237 x 194 x 162 mm
9.33 x 7.64 x 7.38 inch
Process temperature
-20 to 60 °C (0 to 140 °F)
Ingress protection
IP66 / IP67
Input
1 to 2x Memosens digital input
2x 0/4 to 20mA input optional
2x Digital input optional
Output / communication
2 to 4x 0/4 to 20 mA current outputs,
Alarmrelay, 2x relay
Certificates, declarations and approvals
EAC, cCSAus, MCERTS
Measuring principle
Ultrasonic sensor
Application
Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Characteristic
Robust plastic housing
All non-ex applications
Design
2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Material
Housing base: PC-FR
Housing seal: EPDM
Dimension
237 x 194 x 162 mm
9.33 x 7.64 x 7.38 inch
Process temperature
-20 to 60 °C (0 to 140 °F)
Ingress protection
IP66 / IP67
Input
1 to 2x Memosens digital input
2x 0/4 to 20mA input optional
2x Digital input optional
Output / communication
2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay, ProfibusDP, Modbus RS485, Modbus TCP, Ethernet
Certificates, declarations and approvals
EAC, cCSAus, MCERTS
Measuring principle
Fluorescence measurement
Measuring principle
UV photometric
Characteristic
Robust plastic housing
All non-ex applications
Design
2x Memosens input, 2 to 4x current output, Alarmrelay
2x relay, SD card for software update and copy & paste of setup
Process temperature
-20 to 60 °C (0 to 140 °F)
Application
Modular 4 wire controller
Multichannel: 1/2 digital channels for Memosens protocol
Multiparameter: pH, redox, ISFET, conductivity inductive and conductive, dissolved oxygen, nitrate and turbidity
Two sensors connectable in any combination
Functionality modular extendable at any time
Plug and play for modules and sensors
Output / communication
2 to 8x 0/4 to 20 mA current outputs
Alarmrelay, 2x relay
Input
1 to 2x Memosens digital input
Measuring principle
Potentiometric
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
Sensor ORP / Redox
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
Conductive
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Tauchrohr Durchmesser: 40 mm (1.57 Zoll)
Länge: 600, 1200, 1800 und 2400 mm
(23.6, 47.2, 70.9 und 94.5 Zoll)
Process temperature
0 ... 60 °C (32 ... 140 °F)
Measuring principle
Amperometric oxygen measurement
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
Total chlorine
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
Single beam scattered light
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
UV photometric
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Process temperature
0 to 60 °C (32 to 140 °F)
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Measuring principle
Potentiometric
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
The holder system CYH112 works for nearly any type of fixing:
Fixing on the floor, wall or directly on a rail
Material
Main pipe, transverse pipe: stainless steel 1.4404
Chain: PA or stainless steel 1.4401
Process temperature
-20 to 60 °C (-4 to 140 °F)
Measuring principle
Sensor ORP / Redox
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
The holder system CYH112 works for nearly any type of fixing:
Fixing on the floor, wall or directly on a rail
Material
Main pipe, transverse pipe: stainless steel 1.4404
Chain: PA or stainless steel 1.4401
Process temperature
-20 to 60 °C (-4 to 140 °F)
Measuring principle
Conductive
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
The holder system CYH112 works for nearly any type of fixing:
Fixing on the floor, wall or directly on a rail
Material
Main pipe, transverse pipe: stainless steel 1.4404
Chain: PA or stainless steel 1.4401
Process temperature
-20 to 60 °C (-4 to 140 °F)
Measuring principle
Amperometric oxygen measurement
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
The holder system CYH112 works for nearly any type of fixing:
Fixing on the floor, wall or directly on a rail
Material
Main pipe, transverse pipe: stainless steel 1.4404
Chain: PA or stainless steel 1.4401
Process temperature
-20 to 60 °C (-4 to 140 °F)
Measuring principle
Total chlorine
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Characteristic
Simple and easy installation
Universal and flexible
Design
The holder system CYH112 works for nearly any type of fixing:
Fixing on the floor, wall or directly on a rail
Material
Main pipe, transverse pipe: stainless steel 1.4404
Chain: PA or stainless steel 1.4401
Process temperature
-20 to 60 °C (-4 to 140 °F)
Measuring principle
Single beam scattered light
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYH112 is a modular holder system for sensors and assemblies in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
The holder system CYH112 works for nearly any type of fixing:
Fixing on the floor, wall or directly on a rail
Material
Main pipe, transverse pipe: stainless steel 1.4404
Chain: PA or stainless steel 1.4401
Process temperature
-20 to 60 °C (-4 to 140 °F)
Measuring principle
UV photometric
Characteristic
Simple and easy installation
Universal and flexible
Design
The holder system CYH112 works for nearly any type of fixing:
Fixing on the floor, wall or directly on a rail
Process temperature
-20 to 60 °C (-4 to 140 °F)
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Measuring principle
Optical sensor
Measuring principle
Sensor ORP / Redox
Measuring principle
Single beam scattered light
Measuring principle
Potentiometric
Measuring principle
Ozone
Measuring principle
Amperometric oxygen measurement
Measuring principle
Conductive