Specifications

Product headline
Calculated volume or mass flow measurement. dp primary element (orifice). Special designs.
Sensor features
Internationally standardized. Nominal pipe size DN10...2000 ; 3/8...80". Meter runs. Weld-In versions. Compact or remote design. Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown. Deltabar S/M differential pressure transmitter.
Nominal diameter range
DN 10...2000 3/8" ... 80"
Max. measurement error
typically < 1% of calculated volume or mass acc. ISO5167 without calibration.
Measuring range
0.02 ... 70'000m3/h
Max. process pressure
PN2,5 ... 400 Cl.150 ... 4500
Medium temperature range
Compact version: -200°C ... 200°C -328°F ... 392°F Remote version: -200°C ... 1000°C -328°F ... 1832°F
Degree of protection
Transmitter (Deltabar): IP67 NEMA6P
Display/Operation
Transmitter (Deltabar): 4-line display 3 push buttons Quick setup HistoROM
Outputs
Transmitter (Deltabar): 4 ... 20 mA
Digital communication
Transmitter (Deltabar): HART PROFIBUS PA FOUNDATION Fieldbus
Hazardous area approvals
Transmitter (Deltabar): ATEX FM CSA IEC TIIS NEPSI
Product headline
Calculated volume or mass flow measurement. dp primary element (orifice). Special designs.
Sensor features
Internationally standardized. Nominal pipe size DN10...2000 ; 3/8...80". Meter runs. Weld-In versions. Compact or remote design. Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown. Deltabar S/M differential pressure transmitter.
Nominal diameter range
DN 10...2000 3/8" ... 80"
Max. measurement error
typically < 1% of calculated volume or mass acc. ISO5167 without calibration. Uncertainty of primary element excluding uncertainty of density or compensation.
Measuring range
0.4 ... 600'000 m3/h 2.0 kg/h ... 3'000 t/h at 10bar/230°C
Max. process pressure
PN2,5 ... 400 Cl.150 ... 4500
Medium temperature range
Compact version: -200°C ... 200°C -328°F ... 392°F Remote version: -200°C ... 1000°C -328°F ... 1832°F
Degree of protection
Transmitter (Deltabar): IP67 NEMA6P
Display/Operation
Transmitter (Deltabar): 4-line display 3 push buttons Quick setup HistoROM
Outputs
Transmitter (Deltabar): 4 ... 20 mA
Digital communication
Transmitter (Deltabar): HART PROFIBUS PA FOUNDATION Fieldbus
Hazardous area approvals
Transmitter (Deltabar): ATEX FM CSA IEC TIIS NEPSI
Product headline
Calculated volume or mass flow measurement. dp primary element (orifice). Special designs.
Sensor features
Internationally standardized. Nominal pipe size DN10...2000 ; 3/8...80". Meter runs. Weld-In versions. Compact or remote design. Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown. Deltabar S/M differential pressure transmitter.
Nominal diameter range
DN 10...2000 3/8" ... 80"
Max. measurement error
typically < 1,5% of calculated volume or mass acc. ISO5167 without calibration. Uncertainty of primary element excluding uncertainty of density or compensation."
Measuring range
0.4 ... 600'000 m³/h
Max. process pressure
PN2,5 ... 400 Cl.150 ... 4500
Medium temperature range
Compact version: -200°C ... 200°C -328°F ... 392°F Remote version: -200°C ... 1000°C -328°F ... 1832°F
Degree of protection
Transmitter (Deltabar): IP67 NEMA6P
Display/Operation
Transmitter (Deltabar): 4-line display 3 push buttons Quick setup HistoROM
Outputs
Transmitter (Deltabar): 4 ... 20 mA
Digital communication
Transmitter (Deltabar): HART PROFIBUS PA FOUNDATION Fieldbus
Hazardous area approvals
Transmitter (Deltabar): ATEX FM CSA IEC TIIS NEPSI