Information
Information
Metric TC thermometer with dual ceramic thermowell for high-temperature applications
The TAF12D are assemblies with double ceramic protection tubes, designed specifically for applications such as ceramic baking ovens, brickworks, porcelain production and glass industries. They contain a single or double TC insert in ceramic insulators.
Process temperatures: up to +1700 °C (+3092 °F)
Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance
Long term stable measurement due to sensor protection with non-porous materials
Flexible product selection by modular design
Optimized life cycle costs by means of replaceable spare parts
Documentation
Specifications
Accuracy
class 2 acc. to IEC 60584
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
Operating temperature range
Type S:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type R:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type B:
600 °C ...1.700 °C
(1.112 °F ...3.092 °F)
Max. immersion length on request
up to 3.500,00 mm (137,80'')
Measuring principle
Thermocouple
Characteristic / Application
metric style
modular temperature assembly
high temperature probe (furnace)
incl. double ceramic thermowell
Thermowell / protection tube
ceramic protection tube and inner tube
Insert / probe
ceramic capilarry, rigid
Outer diameter protection tube / Insert
14,0 mm (0,55")
15,0 mm (0,59")
Max. immersion length on request
up to 3.500,00 mm (137,80'')
Material protection tube/ thermowell
Ceramic (C610/C799)
Process connection
compression fitting:
G3/4"
G1"
G11/2"
adjustable Flange
Tip shape
straight
Operating temperature range
Type S:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type R:
0 °C ...1.600 °C
(32 °F ...2.912 °F)
Type B:
600 °C ...1.700 °C
(1.112 °F ...3.092 °F)
Max. process pressure (static)
at 20 °C: 1 bar (15 psi)
Accuracy
class 2 acc. to IEC 60584
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Certification
SIL (transmitter only)