Radiometric Level and density Source Container FQG66

Radiometric Level and density Source Container FQG66

Category:Level
Information

Information

Radiation source container with sliding source support rod for manual or pneumatic on/off switching

Encloses the radioactive source used for radiometric point level detection, level and density measurement. Operating with very high sensitivity rod scintillation detectors, provide lowest possible radiation loads in the surrounding.

Used if the shielding effectiveness of smaller source containers (FQG61/62) are too low

Activity: 137Cs 740GBq (20,000mCi), 60Co to 185GBq (5,000mCi)

Process temperature: No limitation (extraneous)

Process pressure: No limitation (extraneous)

High safety level thanks to highest safety classification for the source supplied (DIN 25426/ISO 2919, typically classification C66646) and simple and easy source replacement

Extremely high shielding ensures that no control areas are generally required and that installation in accessed areas is possible

Additional metallic protective capsule with O-ring seal to protect the source against mechanical and chemical influences

Low space requirement and simple mounting and various angles of emission for optimum adaption to the application

Padlock for fixation the on/off switch position and to protect against theft

Easy identification of switch status through sight glasses on the cover or by remote display with proximity switches

Radiometric measuring principle

Specifications

Process temperature
Any
Process pressure / max. overpressure limit
Any
Main wetted parts
Non-contact
Measuring principle
Radiometric
Characteristic / Application
Source container Emission angle: 40 / 20 degrees 435kg
Specialities
Sliding source support rod for manual or pneumatic on/ off switching
Ambient temperature
-55 °C...+100 °C (-67 °F...+212 °F)
Process temperature
Any
Process pressure / max. overpressure limit
Any
Main wetted parts
Non-contact
Process connection
Non-contact
Measuring principle
Radiometric
Characteristic / Application
Source container Emission angle: 40 / 20 degrees 435kg
Specialities
Control area calculation with Applicator
Ambient temperature
-55 °C...+100 °C (-67 °F...+212 °F)
Process temperature
Any
Process pressure / max. overpressure limit
Any
Main wetted parts
Non-contact
Process connection
Non-contact
Measuring principle
Radiometric Limit
Characteristic / Application
Source container Emission angle: 5 degrees Approximately 435 kg
Specialities
Control area calculation with Applicator
Ambient temperature
-55 °C ... +100 °C (-67 °F ...+212 °F)
Process temperature
Any
Process pressure / max. overpressure limit
Any
Main wetted parts
Non- contact
Process connection
Non- contact
Process connection hygienic
Non- contact
Measuring principle
Radiometric Limit
Characteristic / Application
Source container Emission angle: 5 degrees 435kg
Specialities
Control area calculation with Applicator
Ambient temperature
-55 °C...+100 °C (-67 °F...+212 °F)
Process temperature
Any
Process pressure / max. overpressure limit
Any
Main wetted parts
Non- contact
Process connection
Non- contact
Process connection hygienic
Non- contact
Measuring principle
Radiometric Density
Characteristic / Application
Source container Emission angle: 5/ 20 / 40 degrees 435kg
Ambient temperature
-55 °C...+100 °C (-67 °F...+212 °F)
Process temperature
Any
Process pressure
Any
Wetted parts
Non-contact
Hygienic
Non-contact
Specialities
Control area calculation with Applicator