Radiometric Point level detection Gammapilot FTG20

Radiometric Point level detection Gammapilot FTG20

Category:Level
Information

Information

Geiger-Mueller counter for point level detection with separate transmitter

For liquids, solids, suspensions and sludges etc. Particularly for applications under extreme measuring conditions, e.g. high pressure, high temperature, corrosiveness, toxicity, abrasion. All kinds of process vessels, e.g. reactors, autoclaves, separators, acid tanks, mixers, cyclones, cupola furnaces.

Temperature: No limitation (non-invasive, extraneous)

Pressure: No limitation (non-invasive, extraneous)

Switch time: Up to 0.4 seconds

International explosion protection certificates

Sensor and transmitter: One instrument for all measuring tasks - can be used universally due to numerous certificates and approvals

Highest availability, reliability and safety, even for extreme process and ambient conditions

No recalibration after electronics exchange because of HistoROM data management concept and automatic decay compensation

Optimum adjustment to the respective application via a variety of sensitivity versions

Relay, 8/16mA (passive - two-wire loop powered) or 4 to 20mA output for easy system integration

Aluminum or stainless steel housing for heavy-duty applications

Easy commissioning and fast, on-site operation

Radiometric measuring principle

Specifications

Process temperature
Any
Process pressure / max. overpressure limit
Any
Min. density of medium
Any
Min. conductivity of medium
Any
Measuring principle
Radiometric Limit
Characteristic / Application
Radiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in liquids, sludge or suspensions under exteme process conditions
Specialities
Calculation and sizing with Applicator
Supply / Communication
Relay DPDT: 19...253VAC, 19...55VDC 8/16mA: 11...36VDC, 11..30VDC (Exia)
Ambient temperature
Relay DPDT: 19...253VAC, 19...55VDC 8/16mA: 11...36VDC, 11..30VDC (Exia)
Process temperature
Any
Process pressure / max. overpressure limit
Any
Min. density of medium
Any
Min. conductivity of medium
Any
Main wetted parts
Non-contact
Process connection
Non-contact
Process connection hygienic
Non-contact
Sensor length
140 mm (5.5")
Communication
Relay DPDT 8/16mA 4...20mA
Certificates / Approvals
ATEX, CSA, CSA C/US, IEC Ex, NEPSI, EAC
Options
Sensitivity: 1x Geiger- counter: 1-8uSv/h, 2x Geiger- counter: 0,5-4uSv/h 3x Geiger- counter: 0,3-2,7uSv/h Cooling jacket Transmitter with compartment for conduit
Components
Isotope: FSG60, FSG61 Source container: FQG60, FQG61, FQG62, FQG63, QG2000
Measuring principle
Radiometric Limit
Characteristic / Application
Radiometric Transmitter with 1 to 3 Geiger-Müller counters for contactless measurement in solids under exteme process conditions
Specialities
Calculation and sizing with Applicator
Supply / Communication
Relay DPDT: 19...253VAC, 19...55VDC 8/16mA: 11...36VDC, 11..30VDC (Exia)
Ambient temperature
-40...70°C, (-40...158°F), With cooling jacket: 0...120°C (32...248°F)
Process temperature
Any
Process pressure / max. overpressure limit
Any
Min. density of medium
Any
Main wetted parts
Non-contact
Process connection
Non-contact
Process connection hygienic
Non-contact
Sensor length
140 mm (5.5")
Communication
Relay DPDT 8/16mA 4...20mA
Certificates / Approvals
ATEX, CSA C/US, IEC Ex, NEPSI, EAC
Options
Sensitivity: 1x Geiger- counter: 1-8uSv/h, 2x Geiger- counter: 0,5-4uSv/h 3x Geiger- counter: 0,3-2,7uSv/h Cooling jacket Transmitter with compartment for conduit
Components
Isotope: FSG60, FSG61 Source container: FQG60, FQG61, FQG62, FQG63, QG2000