Self-cleaning backflush filter for sampling from pressurized pipes and outlets
Liquiline System CAT810 is designed for:
Outlets of municipal and industrial wastewater treatment plants
Collection of aqueous samples from pressurized pipes in industrial processes
Long maintenance intervals due to automatic back-flush function
Save costs through tool-free maintenance and easy replacement of filter elements
Control via the user-friendly Liquiline System analyzer for perfect synchronization of the measuring point or timer-controlled operation
Various mounting options for optimum fit to the application
Short response time of downstream measuring devices thanks to low dead volume
Documentation
Specifications
Process temperature
4 to 40 °C (39 to 104 °F)
Process pressure
1.5 to 4.0 bar (21.76 to 58.01 psi)
For optional automatic cleaning:
2.0 to 5.0 bar (29.0 to 72.5 psi); but at least 0.5 bar (7.3 psi) > process pressure
Measuring principle
Colorimetric
Characteristic
Automatic sample preparation system for supplying process measuring devices with filtered samples from pressurized pipes
Size
Panel version:
870 x 350 x 177 mm
34.25 x 13.78 x 6.97 inch
Prepared for stand housing CA80:
828 x 327 x 327 mm
32.6 x 12.87 x 12.87 inch
Basic version:
811 x 303 x 131 mm
31.93 x 11.93 x 5.16 inch
Design
Back-wash filter system with various mounting options:
Panel version, Prepared for stand housing of CA80, Basic version - filter unit
Process temperature
4 to 40 °C (39 to 104 °F)
Ambient temperature
4 to 40 °C (39 to 104 °F)
Process pressure
1.5 to 4.0 bar (21.76 to 58.01 psi)
For optional automatic cleaning:
2.0 to 5.0 bar (29.0 to 72.5 psi); but at least 0.5 bar (7.3 psi) > process pressure
Specials
Optional back-flush with pressurizd air or water
Controling and parametrition via Lquiline System CA80
Stand-alone version with time-control available
Application
Sampling from pressurized pipes
Preliminary and secondary clarification of municipal and industrial wastewater treatment plants
Sampling of aqueous media from industrial processes
Power supply
100 to 120/200 to 240 V AC ±10%, 50/60 Hz