Servo tank gauging instrument Proservo NMS80

Servo tank gauging instrument Proservo NMS80

Category:Level
Information

Information

High precision servo measurement for liquid level, interface and density

For high accuracy custody transfer measurement in crude oil, gasoline, diesel, petrochemicals and chemicals.

Process connections: Flanges

Temperature: -200 to +200°C (-328 to +392°F)

Pressure: 0 to +6bar (0 to +87psi)

Maximum measuring range: 36m (118ft)

Accuracy: ±0.4mm (±0.02")

International explosion protection and custody transfer certificates, overfill prevention WHG, SIL

Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy) for high level of safety

Maximum reliability through accuracy up to ±0.4mm (±0.02")

Developed according to international metrology recommendations such as OIML R85 and API MPMS

Local and country-specific certifications like NMi or PTB for custody transfer applications

Simplified installation and trouble-free operations due to easy connection to major DCS systems via open protocols

Measurement of interfaces between up to three liquid layers, tank bottom, spot, and profile densities

Specifications

Accuracy
up to 0.4 mm
Process temperature
-200°C...200°C (-328°F...392°F)
Process pressure / max. overpressure limit
0,2...6 bar abs
Max. measurement distance
36 m (118 ft)
Main wetted parts
316L, AlloyC276, PTFE
Measuring principle
Servo / Float Tank Gauging
Characteristic / Application
Servo Tank Gauging: High precision measurement for liquid level, interface, spot density, profile density
Specialities
Custody transfer level measurement Interface measurement Spot density, density profile measurement
Supply / Communication
85-264VAC 52-74VAC 19-64VDC
Accuracy
up to 0.4 mm
Ambient temperature
Standard: -40°C…60°C (-40°F...140°F) For calibration to regulatory standards: -25°C…55°C (-13°F...131°F)
Process temperature
-200°C...200°C (-328°F...392°F)
Process pressure / max. overpressure limit
0,2...6 bar abs
Main wetted parts
316L, AlloyC276, PTFE
Process connection
Flange: DN80/3" / DN150/6"
Max. measurement distance
36 m (118 ft)
Communication
Outputs: Fieldbus: Modbus RS485, V1, WM550 HART, BPM and TRL/2 (via GE option) Analog 4-20mA output (Exi/ Exd) Relay output (Exd) Inputs: Analog 4-20mA input (Exi/ Exd) 2-, 3-, 4-wire RTD input Discrete input (Exd, passive/ active)
Certificates / Approvals
ATEX, FM, IEC Ex, EAC, JPN Ex, KC Ex, INMETRO, NEPSI, UK Ex
Safety approvals
Overfill protection WHG SIL
Metrological approvals and certificates
OIML, NMi, PTB
Options
Redundant fieldbus Weather protection cover Guide wire assembly Relief valve Gas purging nozzle connection Pressure gauge Cleaning nozzle connection
Application limits
Stilling well or guide wires for turbulent application Recommend PTFE displacer for high viscosity application Recommend AlloyC276 displacer for corrosive application Interface measurement requires min. difference of 0.100 g/ml between layers
Measuring principle
Servo / Float Tank Gauging
Characteristic / Application
Servo Tank Gauging: High precision measurement for liquid level, interface, spot density, profile density
Supply / Communication
85-264VAC
Ambient temperature
Standard: -40°C…60°C (-40°F...140°F) For calibration to regulatory standards: -25°C…55°C (-13°F...131°F)
Process temperature
-200°C...200°C (-328°F...392°F)
Process pressure
0.2...6 bar abs
Wetted parts
316L, AlloyC276, PTFE
Output
Outputs: Fieldbus: Modbus RS485, V1, HART Analog 4-20mA output (Exi/ Exd) Relay output (Exd) Inputs: Analog 4-20mA input (Exi/ Exd) 2-, 3-, 4-wire RTD input Discrete input (Exd, passive/ active)
Certificates / Approvals
ATEX, FM, IEC Ex, NEPSI, EAC
Options
Weather protection cover Guide wire assembly Relief valve Gas purging nozzle connection Pressure gauge Cleaning nozzle connection
Specialities
Custody transfer level measurement Interface measurement Spot density, density profile measurement
Measuring range
36 m (118 ft)
Other approvals and certificates
OIML, NMi, PTB