Информация
Информация
Smart pressure transmitter with metal membrane for highly accurate measurement of liquids and gases
With welded separator
Pressure measuring range: up to 400 bar (6000 psi)
Process temperatures up to 400°C (752 °F) with diaphragm seal
Accuracy: up to +/- 0.055%
Reduce systematic failures - error free SIL commissioning and instrument guided proof testing
Reduce on site accidents and protect equipment when instruments are in difficult to reach areas
Wireless control of the device in the process area with the SmartBlue App without process interruption
Документация
Спецификации
Accuracy
Standard:
up to 0.075 %
Platinum
up to 0.055 %
Process temperature
Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-40°C...+400°C
(-40°F...+752°F)
Pressure measuring range
400 mbar... 400 bar
(6psi...6,000psi)
Main wetted parts
316L, AlloyC,
Tantal, Monel,
PTFE
Material process membrane
316L, AlloyC,
Tantal, Monel,
PTFE
Measuring cell
400 mbar...400 bar
(6psi...6,000psi)
Measuring principle
Absolute and gauge pressure
Characteristic
Pressure transmitter with metal membrane for accurate measurement in liquids or gases.
Available with diaphragm seals.
Intuitive and clear wizard for commissioning
Supply voltage
Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC
Reference Accuracy
Standard:
up to 0.075 %
Platinum:
up to 0.055 %
Long term stability
0.1% of URL/year
0.2% of URL/ 5 years
0.25% of URL/ 10 years
Process temperature
Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-70°C...+400°C
(-x°F...+752°F)
Ambient temperature
-40°C...+85°C
(-40°F...+185°F)
Measuring cell
400 mbar...400 bar
(6psi...6,000psi)
Smallest calibratable span
20 mbar (0.3 psi)
Vacuum resistance
Standard:10 mbar (0.145 psi)
Diaphragm seal: 50 mbar (0.725 psi)
Max. Turn down
100:1
Max. overpressure limit
600 bar (9,000 psi)
Process connection
Thread:
G1/2...G2, R1/2, MNPT3/4...MNPT2,
FNPT1/2
Flange:
DN25...DN80,
NPS 1"...3"
Process connection hygienic
Process connection hygienic
Material process membrane
316L, AlloyC,
Tantal, Monel,
PTFE
Material gasket
PTFE
Fill fluid
Silicone oil, Inert oil,
Vegetable oil,
High/ low temperature oil
Material housing
Aluminium
Communication
4...20 mA,
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI
Safety approvals
SIL
Design approvals
EN10204-3.1,
NACE MR0175,
NACE MR0103
Hygienic approvals
Hygienic approvals
Marine approvals
Marine approvals
Drinking water approvals
NSF
Specialities
Bluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Measuring principle
Absolute and gauge pressure
Characteristic / Application
Pressure transmitter with metal membrane for accurate measurement in liquids or gases.
Available with diaphragm seals.
Intuitive and clear wizard for commissioning
Specialities
Bluetooth® Operation and maintenance SmartBlue App,
RFID TAG for easy identification,
Plug and play functionalities
Supply / Communication
Ex d, Ex e, non-Ex:
10.5...35V DC
Ex i: 10.5...30V DC
Accuracy
Standard:
up to 0.075 %
Platinum
up to 0.055 %
Long term stability
0.1 % of URL/ year
0.2 % of URL/ 5 years
0.25 % of URL/ 10 years
Ambient temperature
-40°C...+85°C
(-40°F...+185°F)
Process temperature
Standard:
-40°C…+125°C
(-40°F…+257°F)
Diaphragm seal:
-40°C...+400°C
(-40°F...+752°F)
Process pressure / max. overpressure limit
700 bar (10,500 psi)
Pressure measuring range
400 mbar... 400 bar
(6psi...6,000psi)
Main wetted parts
316L, AlloyC,
Tantal, Monel,
PTFE
Process connection
Thread:
G1/2...G2, R1/2, MNPT3/4...MNPT2,
FNPT1/2
Flange:
DN25...DN80,
NPS 1"...3"
Max. measurement distance
4000 m (13,123 ft) H2O
Communication
4...20 mA,
4...20 mA HART
PROFINET with Ethernet-APL
Bluetooth® wireless
technology and app (optional)
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI
Safety approvals
SIL
Design approvals
EN 10204-3.1
NACE MR0175,
NACE MR0103,
AD2000
Hygienic approvals
Hygienic approvals
Marine approval
Marine approval
Drinking water approvals
NSF
Options
Diaphragm seal
Application limits
Measuring cell: Metal welded
If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure: hydrostatic pressure