Chromate analyzer Liquiline System CA80CR

Chromate analyzer Liquiline System CA80CR

Категория:Liquid analysis
Информация

Информация

Colorimetric system for the monitoring of industrial wastewater and optimization of process control

Liquiline System CA80CR supports you in improving the environmental performance of your processes by:

Monitoring and optimizing the cleaning capacity of industrial wastewater treatment plants.

Effluent monitoring in tanneries and electroplating plants.

Monitoring of membrane filtration.

Limit monitoring in drinking water applications.

Standardized colorimetric measuring principle - diphenyle carbazide method - guarantees compliance with discharge regulations.

Reduced operating costs through automatic calibration and cleaning and low reagent consumption.

Simple maintenance: no tools required.

Advanced diagnostics with remote access for increased process safety.

Fast commissioning and plug & play thanks to Memosens technology and user-friendly operation.

Easy upgrade of functionality - even to a complete measuring station - simply by adding modules and connecting Memosens sensors. Reduces installation effort.

Drive connectivity: Liquiline Edge Module CYY7 transfers process data to Netilion, independently of the fieldbus. This allows remote overview and the use of IIoT services. It’s available in new products or as upgrade to installed Liquiline platforms.

Chromate concentration in a liquid can be measured using the colorimetric measuring principle. This video shows what it is about and how this measuring principle works.

Документация

Спецификации

Measuring range
0,03 to 2.5 mg/l Cr(VI) 0.2 to 5.0 mg/l Cr(VI) 0.2 to 5.0 mg/l with dilution function to maximum 10 to 250 mg/l Cr(VI)
Process temperature
4 to 40 °C (39 to 104 °F)
Process pressure
At atmospheric pressure, < 0.2 bar absolute
Measuring principle
Colorimetric
Characteristic
Analyzer for Chromate (Chrome VI) in aqueous solutions
Size
Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in
Design
Open design, cabinet and stand housing High-Performance plastic ASA-PC, additional stand coated steel
Process temperature
4 to 40 °C (39 to 104 °F)
Ambient temperature
5 to 40 °C (41 to 104 °F) Outdoor version: - 20 to 40 °C (-4 to 104 °F)
Process pressure
At atmospheric pressure, < 0.2 bar absolute
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
Consistency of the sample
Suspended solids content Turbitity < 50 NTU, aqueous, homogenized
Specials
Easy upgrade to measuring station with up to four digital Memosens sensors Automatic calibration and cleaning User-configurable measuring, cleaning and calibration intervals Optional cooling module for longer reagent shelf life 2 channel version optional User-definable measuring ranges Modular design for easily extensible functionality Digital communication for remote access
Application
Limit value monitoring of Chromate in potable water and waste water Common applications are industrial waste water Monitoring for tanneries and the galvanic industry
Power supply
100 to 120 VAC / 200 to 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 or 60 ± 1,2 Hz
Output / communication
2x 0/4 to 20 mA Modbus RS485/TCP (optional) Ethernet (optional) Alarmrelay
Input
1 or 2 measuring channels 1 to 4 digital sensor inputs for sensors with Memosens protocol (optional)
Measuring range
0,03 to 2.5 mg/l Cr(VI) 0.2 to 5.0 mg/l Cr(VI) 0.2 to 5.0 mg/l with dilution function to maximum 10 to 250 mg/l Cr(VI)
Consumables
Reagents and standard solutions CY80CR as well as cleaner CY800 are necessary for the operation Regular maintenance is done with the parts of the maintenance kit CAV800