Информация
Информация
Fundamental metric RTD direct contact thermometer for hygienic applications
Specially designed for use in hygienic and aseptic applications in the Food & Beverages and Life Sciences industries
Measuring range: –50 to +200 °C (–8 to +392 °F)
Pressure range up to 50 bar (725 psi)
Protection class: up to IP69K
Can be used in non-hazardous areas
Excellent value for money and fast delivery
User-friendly and reliable from product selection to maintenance
International certification: hygiene standards as per 3-A® , EHEDG, ASME BPE, FDA, TSE Certificate of Suitability
Wide range of process connections
Документация
Спецификации
Accuracy
class A acc. to IEC 60751
Response time
depending on configuration
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
Operating temperature range
PT100:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. immersion length on request
up to 400 mm (15,75")
Measuring principle
Resistance Temperature Detector
Characteristic / Application
metric style
hygienic applications
aseptic applications
hygienic process connections
with neck
Thermowell / protection tube
without (not intended to use with thermowell)
Insert / probe
without exchangeable insert
Outer diameter protection tube / Insert
6,0 mm (0,24")
8,0 mm (0,31")
Max. immersion length on request
up to 400 mm (15,75")
Material protection tube/ thermowell
316L
Process connection
compression fitting
triclamp
microclamp
clamp connections acc. to ISO2852
Ingold
G3/4" Liquiphant
G1" Liquiphant
Varivent
SMS 1147
screwed pipe joint acc. to DIN 11851
Tip shape
straight
reduced
Surface roughness Ra
0,76 μm (30 μin)
0,38 μm (15 μin)
Operating temperature range
PT100:
-50 °C … 200 °C
(-58 °F … 392 °F)
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
Accuracy
class A acc. to IEC 60751
Response time
depending on configuration
Integration head transmitter
yes (4 ... 20 mA, HART)
Certification
SIL (transmitter only)