Proline Prosonic Flow G 300 ultrasonic flowmeter

Proline Prosonic Flow G 300 ultrasonic flowmeter

Категория:Flow measurement
Информация

Информация

Highly robust gas specialist for fluctuating conditions with compact, easily accessible transmitter

Proline Prosonic Flow G 300 for natural and process gas measurement in the chemical and in the oil and gas industries.

3D QR code for Prosonic Flow G

The measuring principle is unaffected by gas composition

Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.

Device properties:

Direct measurement: flow, pressure & temperature

Wetted parts: titanium / 316L

Maximum measuring accuracy: 0.5 %

Compact dual-compartment housing with up to 3 I/Os

Backlit display with touch control and WLAN access

Remote display available

Flexible device with user-definable gas mixtures for demanding measuring tasks

Maximum reliability even with humid or wet gas – sensor design insensitive to condensate

High-performance process control – real-time pressure- and temperature-compensated values

Efficient solution – multivariable, no pressure loss

Full access to process and diagnostic information – numerous, freely combinable I/Os

Reduced complexity and variety – freely configurable I/O functionality

Integrated verification – Heartbeat Technology

Check it out! Scan the code, download the 3D QR app and explore Prosonic Flow G on your own.

The Ultrasonic Flow Measuring Principle

Документация

Спецификации

Max. measurement error
Volume flow (standard): ‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s) ‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s) Volume flow (optional calibration): ‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s) ‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s) Corrected volume flow (standard): ‐ ±1.2 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s) ‐ ±2.1 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s) Corrected volume flow (optional calibration): ‐ ±0.8 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s) ‐ ±1.2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s) Sound Velocity: ±0.2 % o.r.
Measuring range
Gas: 0.3 m/s to 40 m/s
Medium temperature range
-50 to 150 °C (-58 to +302°F) -50 to 100 °C (-58 to +212°F) with integrated pressure cell
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M) Transducer: 1.4404 (316, 316L), Titan Grade 2
Measuring principle
Ultrasonic flow
Product headline
Highly robust gas specialist for fluctuating process conditions with compact, easily accessible transmitter. Flexible device with user-definable gas mixtures for demanding measuring tasks. Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.
Sensor features
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate. High-performance process control – real-time pressure- and temperature-compensated values. Efficient solution – multivariable, no pressure loss. Direct measurement: flow, pressure & temperature. Wetted parts: titanium / 316L. Maximum measuring accuracy: 0.5 %.
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range
DN 25 to 300 (1 to 12")
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M) Transducer: 1.4404 (316, 316L), Titan Grade 2
Measured variables
Volume flow, corrected volume flow, mass flow, flow velocity, speed of sound, pressure, temperature, density, dynamic viscosity, energy flow, Wobbe index, methane fraction, calorific value, molar mass
Max. measurement error
Volume flow (standard): ‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s) ‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s) Volume flow (optional calibration): ‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s) ‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s) Corrected volume flow (standard): ‐ ±1.2 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s) ‐ ±2.1 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s) Corrected volume flow (optional calibration): ‐ ±0.8 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s) ‐ ±1.2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s) Sound Velocity: ±0.2 % o.r.
Measuring range
Gas: 0.3 m/s to 40 m/s
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
Medium temperature range
-50 to 150 °C (-58 to +302°F) -50 to 100 °C (-58 to +212°F) with integrated pressure cell
Ambient temperature range
-40 to 60 °C(-40 to +140 °F) Optional: -50 to 60 °C(-58 to +140 °F)
Sensor housing material
Stainless Steel, 1.4404(316/316L), 1.4408/1.4409 (CF3M)
Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L Polycarbonate
Degree of protection
Compact version: IP66/67, type 4X enclosure. Optional: External WLAN antenna: IP67
Display/Operation
4-line backlit display with Touch Control (operation from outside) Configuration via local display and operating tools possible Remote display available
Outputs
3 outputs: 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Double pulse output (active/passive) Relay output
Inputs
Status input 4-20 mA input
Digital communication
HART, Modbus RS485
Power supply
24V DC 100 to 230 V AC AC 100 to 230 V / DC 24 V (non harzardous area)
Hazardous area approvals
ATEX, IECEx, cCSAus, JPN, EAC, UK Ex, KC
Product safety
CE, C-tick
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material NACE MR0175/MR0103