Proline t-mass I 300 thermal mass flowmeter

Proline t-mass I 300 thermal mass flowmeter

Категория:Flow measurement
Информация

Информация

Insertion flowmeter with long-term stability and a compact, easily accessible transmitter

Proline t-mass I 300 – Insertion version for pipes/ducts up to DN 1500 (60")

Discover t-mass F and I via 3D QR code

Measuring principle is characterized by a high operable flow range and direct mass flow measurement

Measurement of utility and process gases and gas mixtures in circular piping or rectangular ducts

Device properties

Insertion version for DN 80 to 1500 (3 to 60")

Bidirectional measurement; high measuring performance

Patented drift-free sensor with SIL 2

Compact dual-compartment housing with up to 3 I/Os

Backlit display with touch control and WLAN access

Remote display available

Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof

High level of process control – premium measurement accuracy and repeatability

Reliable monitoring – detection of process disturbances and reverse flow

Flexible installation – suitable for large dimensional range and circular pipes or rectangular ducts

Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses

Reduced complexity and variety – freely configurable I/O functionality

Integrated verification – Heartbeat Technology

Proline t-mass F/I 300/500 – The thermal mass flowmeter with long-term stability and a keen sense for utility gases

The Thermal Flow Measuring Principle

Документация

Спецификации

Max. measurement error
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Measuring range
20 to 733501 kg/h (44 to 1669340 lb/h)
Medium temperature range
-40 °C to +180°C (-40 °F to +356°F)
Max. process pressure
-0.5 to 20 bar_g (-7.25 to 290 psi_g)
Wetted materials
Materials for insertion tube Stainless steel, 1.4404 (316/316L) Process connections, process coupling Stainless steel, 1.4404 (316/316L) Sensing element Unidirectional Stainless steel, 1.4404 (316/316L) Alloy C22, 2.4602 (UNS N06022); Bidirectional Stainless steel, 1.4404 (316/316L) Reverse flow detection Stainless steel, 1.4404 (316/316L) Clamping rings PEEK PVDF 1.4404 (316/316L) Flat ring seal EPDM FKM
Measuring principle
Thermal
Product headline
Insertion flowmeter with long-term stability and a compact, easily accessible transmitter. Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof. Measurement of utility and process gases as well as gas mixtures in circular piping or rectangular ducts.
Sensor features
High level of process control – premium measurement accuracy and repeatability. Reliable monitoring – detection of process disturbances and reverse flow. Flexible installation – suitable for large dimensional range and circular pipes or rectangular ducts. Insertion version for DN 80 to 1500 (3 to 60"). Bidirectional measurement; high measuring performance. Patented drift-free sensor with SIL 2.
Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology. Compact dual-compartment housing with up to 3 I/Os. Backlit display with touch control and WLAN access. Remote display available.
Nominal diameter range
DN 80 to 1500 (3 to 60")
Wetted materials
Materials for insertion tube Stainless steel, 1.4404 (316/316L) Process connections, process coupling Stainless steel, 1.4404 (316/316L) Sensing element Unidirectional Stainless steel, 1.4404 (316/316L) Alloy C22, 2.4602 (UNS N06022); Bidirectional Stainless steel, 1.4404 (316/316L) Reverse flow detection Stainless steel, 1.4404 (316/316L) Clamping rings PEEK PVDF 1.4404 (316/316L) Flat ring seal EPDM FKM
Measured variables
Massflow, temperature, standard volume flow, volume flow, Free air delivery, velocity, heat flow, energy flow, density
Max. measurement error
Gas: 1.0% o.r. (10 to 100% o.f.s.), 0.1% o.f.s. (1 to 10% o.f.s.)
Measuring range
20 to 733501 kg/h (44 to 1669340 lb/h)
Max. process pressure
-0.5 to 20 bar_g (-7.25 to 290 psi_g)
Medium temperature range
-40 °C to +180°C (-40 °F to +356°F)
Ambient temperature range
-40 to 60°C (-40 to 140°F) Optional: Transmitter: -50 to 60°C (-50 to 140°F), Sensor: -60 to 60°C (-60 to 140°F)
Transmitter housing material
Aluminium, AlSi10Mg, coated Polycarbonate
Degree of protection
IP66/67, Type 4X enclosure
Display/Operation
4-line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible Remote display available
Outputs
3 outputs: 4-20 mA HART (active/passive) 4-20 mA (active/passive) Pulse/frequency/switch output (active/passive) Relay output
Inputs
Status input 4-20 mA input
Digital communication
HART, Modbus RS485
Power supply
DC 24V AC 100 to 240V
Hazardous area approvals
ATEX, cCSAus, IECEx, NEPSI, JPN, UK Ex, EAC, KC
Product safety
CE, C-tick
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Pressure approvals and certificates
CRN
Material certificates
3.1 material NACE MR0175/MR0103