Документация
Спецификации
Characteristic / Application
metric style
modular temperature assembly
process connection as compression fitting
without neck
Thermowell / protection tube
without (not intended to use with thermowell)
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
3,0 mm (0,12'')
6,0 mm (0,24'')
Max. immersion length on request
up to 10.000,00 mm (393,70'')
Material protection tube/ thermowell
1.4404 (316L)
Process connection
compression fitting:
G1/2"
NPT1/2"
weld in version
Tip shape
straight
reduced
Surface roughness Ra
Not defined
Operating temperature range
PT 100:
-200 °C …600 °C
(-328 °F …1112 °F)
Max. process pressure (static)
at 20 °C: 40 bar (580 psi)
Accuracy
class A acc. to IEC 60751
class AA acc. to IEC 60751
Response time
depending on configuration
t50 = 2 s
t90 = 5 s
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
ATEX II1D Ex ia IIIC, II1G Ex ia IIC T6
ATEX II1/2D Ex ia IIIC,II1G Ex ia IIC T6
ATEX II1G Ex ia IIC T6
ATEX II 3 G Ex nA IIC T6, II3D
NEPSI Ex ia IIC T6, Ex iaD 20 T85-T450
IECEx Ex ia IIC T6 Ga/Gb
NEPSI Ex nA IIC T6
Certification
Gost Metrology
SIL (transmitter only)