TH55 Modular TC thermometer, US style

TH55 Modular TC thermometer, US style

Категория:Temperature
Информация

Информация

Comprehensive and common temperature measurement technology for almost all branches of industry

The TH55 temperature sensors are thermocouple assemblies, designed for use in all types of process industries, including heavy industries, due to their rugged design. They are made up of a magnesium oxide insulated thermocouple as a measurement probe and a thermowell made of barstock material.

The sensor assemblies can be used in process industries such as:

Chemicals

Petrochemicals

Power plants

Refineries

Offshore platforms

One source shopping for temperature measurement solutions. World class transmitter with integrated sensor offering for heavy process industry applications.

Remove and install straight out of the box!

Improved galvanic isolation on most devices (2 kV).

Simplified model structure: Competitively priced, offers great value. Easy to order and reorder. A single model number includes sensor, thermowell and transmitter assembly for a complete point solution.

All iTEMP® transmitters provide long term stability ≤ 0.05% per year

Документация

Спецификации

Accuracy
class 1 acc. to IEC 60584 class 2 acc. to IEC 60584
Response time
63% rt = 1,3 s
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
Operating temperature range
Type T: -270 °C ...400 °C (-454 °F ...752 °F) Type J: -210 °C ... 1.200 °C (-346 °F ...2.192 °F) Type E: -270 °C ... 1.000 °C (-454 °F ...1.832 °F) Type K: -270 °C ...1.372 °C (-454 °F ...2.500 °F) Type N: -270 °C ... 1.300 °C (-454 °F ...2.372 °F)
Max. immersion length on request
up to 30" (762 mm) others on request
Measuring principle
Thermocouple
Characteristic / Application
TA20J - SS - w. or w/o. display TMT142 - aluminium - fieldhousing w. or w/o. display TMT162 - aluminium - fieldhousing w. or w/o. display TMT162 - SS - fieldhousing w. or w/o. display Alu - screwed cover w. chain - E+H blue PP plastic - screwed cover w. chain TA30H - aluminum w. or w/o. display
Thermowell / protection tube
to use with thermowell
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
1/4'' (6,35 mm)
Max. immersion length on request
up to 30" (762 mm) others on request
Material protection tube/ thermowell
Sensor sheath 316 Alloy 600
Optional coating
not applicable
Process connection
Thermowell connection male thread: NPT1/2"
Tip shape
straight
Surface roughness Ra
Not defined
Operating temperature range
Type T: -270 °C ...400 °C (-454 °F ...752 °F) Type J: -210 °C ... 1.200 °C (-346 °F ...2.192 °F) Type E: -270 °C ... 1.000 °C (-454 °F ...1.832 °F) Type K: -270 °C ...1.372 °C (-454 °F ...2.500 °F) Type N: -270 °C ... 1.300 °C (-454 °F ...2.372 °F)
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
Accuracy
class 1 acc. to IEC 60584 class 2 acc. to IEC 60584
Response time
63% rt = 1,3 s
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
transmitter only FM IS CSA IS FM/CSA IS
Certification
SIL (transmitter only)