Thermocouple TC10

Thermocouple TC10

Категория:Temperature

Документация

Спецификации

Characteristic / Application
metric style modular temperature assembly universal range of application suitable for hazardous areas threaded process connection with neck incl. thermowell / protection tube (metal)
Thermowell / protection tube
welded protection tube
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
9,0 mm (0,35'') 11,0 mm (0,43'') 12,0 mm (0,47'')
Max. immersion length on request
up to 10.000,00 mm (393,70'')
Material protection tube/ thermowell
1.4404 (316L) 1.4571 (316Ti) Alloy 600 (2.4816) Alloy C276 (2.4819)
Optional coating
Not defined
Process connection
male thread: G1/2" G3/4" G1" NPT1/2" NPT3/4" M20x1.5 R1/2" R3/4"
Tip shape
straight reduced tapered
Surface roughness Ra
0,8 μm (31,5 μin.)
Operating temperature range
Type K: max. 1.100 °C (max. 2.012 °F) Type J: max. 800 °C) (max. 1.3472 °F)
Max. process pressure (static)
at 20 °C: 75 bar (1088 psi)
Accuracy
class 1 acc. to IEC 60584
Response time
depending on configuration t50 = 6 s t90 = 13 s
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
ATEX II ATEX IECEx NEPSI IECEx EAC Ex
Certification
Gost Metrology SIL (transmitter only)