Thermocouple TC88

Thermocouple TC88

Категория:Temperature

Документация

Спецификации

Characteristic / Application
metric style modular temperature assembly universal range of application suitable for hazardous areas suitable for high process pressures threaded process connection with neck to use with thermowell
Thermowell / protection tube
to use with thermowell
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
Insert Diameter 3,0 mm (0,12'') 6,0 mm (0,24'')
Max. immersion length on request
up to 30.000,00 mm (1.181,10'')
Material protection tube/ thermowell
1.4404 (316L) 1.4571 (316Ti) Alloy 600
Optional coating
Not defined
Process connection
male thread: G1/2" NPT1/2" M14x1.5 M18x1.5
Tip shape
straight
Surface roughness Ra
0,8 μm (31,5 μin.)
Operating temperature range
Type K: max. 1.100 °C (max. 2.012 °F) Type J: max. 800 °C (max. 1.472 °F)
Max. process pressure (static)
at 20 °C: 500 bar (7.252 psi)
Accuracy
class 1 acc. to IEC 60584
Response time
depending on configuration t50 = 1 s t90 = 2 s
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
ATEX II NEPSI IECEx NEPSI EAC Ex
Certification
Gost Metrology SIL (transmitter only)