Документация
Спецификации
Characteristic / Application
US style
modular temperature assembly
hygienic design
hygienic process connection
incl. thermowell / protection tube (metal)
Thermowell / protection tube
bar stock (drilled)
Insert / probe
mineral insulated (MI), flexible
Outer diameter protection tube / Insert
1/2'' (12,70 mm)
3/4'' (19,05 mm)
Max. immersion length on request
up to 2.743 mm (108,00'')
Material protection tube/ thermowell
1.4404 (316L)
Process connection
hygienic:
clamp connections TRI-Clamp / Micro-Clamp
Tip shape
straight
reduced
Surface roughness Ra
0,8 μm (32 μin.)
Operating temperature range
PT 100:
-50 °C ...200 °C
(-58 °F ... 392 °F)
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
Accuracy
class A acc. to IEC 60751
class B acc. to IEC 60751
Response time
depending on configuration
Integration head transmitter
yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals
CSA
FM/CSA IS
FM IS
Certification
3A
FDA
ASME BPE 2002
SIL (transmitter only)