Water hardness analyzer Liquiline System CA80HA

Water hardness analyzer Liquiline System CA80HA

Категория:Liquid analysis
Информация

Информация

Colorimetric system for online monitoring of drinking water and process water

Liquiline System CA80HA supports you in monitoring total water hardness:

To classify water hardness in drinking water

To ensure process water quality in production plants

For monitoring process water, e.g. in pure and ultrapure water or desalination plants, requiring a lower limit of detection, please refer to the low range analyzer Liquiline System CA82HA .

The water hardness analyzer uses the colorimetric phthalein purple method, ensuring direct comparability to lab results

Fast commissioning with plug & play thanks to Memosens technology and user-friendly operation

Reduces operating costs thanks to automatic calibration and cleaning, low reagent consumption and long reagent lifetime with optional cooling module

Easy upgrade of functionality to a complete measuring station - by adding modules and connecting Memosens sensors.

Advanced diagnostics with remote access for increased process safety

Easy, tool-free maintenance

Drive connectivity: Liquiline Edge Module CYY7 transfers process data to Netilion, independently of the fieldbus. This allows remote overview and the use of IIoT services. It’s available in new products or as upgrade to installed Liquiline platforms.

Документация

Спецификации

Measuring range
0 to 80 mg/l CaCO3 0 to 80 mg/l with dilution function to maximum 16 to 1600 mg/l CaCO3
Process temperature
4 to 40 °C (39 to 104 °F)
Process pressure
Unpressurized
Measuring principle
Colorimetric
Characteristic
Process analyzer for hardness in aqueous solutions Comply with standard colorimetric measuring principle - phthalein purple method
Size
Housing (open version): 793 x 530 x 417 mm 31.22 x 20.87 x 16.42 in Housing (closed version): 793 x 530 x 463 mm 31.22 x 20.87 x 18.23 in Housing with base: 1723 x 530 x 463 mm 67.83 x 20.87 x 18.23 in
Design
Open design, cabinet and stand housing High-Performance plastic ASA-PC, additional stand coated steel
Process temperature
4 to 40 °C (39 to 104 °F)
Ambient temperature
5 to 40 °C (41 to 104 °F)
Process pressure
Unpressurized
Sample flow rate
Min. 5 ml/min (0.17 fl.oz/min)
Consistency of the sample
Low solid content (< 50NTU), aqueous homogeneous
Application
Total hardness monitoring in reverse osmosis systems inlets, after ion exchange systems Monitoring of water preparation in processes and drinking water
Power supply
100 ... 120 VAC / 200 ... 240 VAC ± 10% 24 VDC ± 10% 50 ± 1 oder 60 ± 1,2 Hz
Output / communication
2x 0/4 ... 20 mA Webserver, Modbus, Ethernet/IP, Profibus DP
Input
1 or 2 measuring channel 1 ... 4 digital sensor inputs for sensors with Memosens protocol (optional)
Measuring range
0 to 80 mg/l CaCO3 0 to 80 mg/l with dilution function to maximum 16 to 1600 mg/l CaCO3
Consumables
Reagents and standard solutions CY80HA as well as cleaner CY800 are necessary for the operation Regular maintenance is done with the parts of the maintenance kit CAV800