Absolute and gauge pressure Cerabar PMP23

Absolute and gauge pressure Cerabar PMP23

Kateqoriya:Pressure
Məlumat

Məlumat

Cost-effective pressure transducer with fully welded design for the food & beverage industry

Pressure transducer to measure absolute or gauge pressure in gases or liquids.

Process connections: Flush-mounted hygienic connections, flush mounted thread connections

Process temperature: -10°C to +100°C (-40°F to +212°F) and +135°C (+275°F) for max. 1h

Process pressure: 400mbar to +40bar (6 to 600psi)

Accuracy: ±0.3% of span

International explosion protection certificates, hygienic certificates

Easy and time-saving installation and set up within the plant due to very compact construction and customizable measuring ranges

IO-Link reduces costs and complexity due to easy configuration via simple configuration tools or through the engineering system

Fully welded process connections maximize process safety by minimizing the use of gaskets

Enhanced process availability is ensured by the stringent use of 316L material and the possibility of IP 69 ingress protection for washdown conditions, as well as the high reproducibility and long-term stability of the product

A high flexibility of use and therefore lower storage costs are guaranteed as the PMP23 is suitable for CIP / SIP cleaning

The PMP23 can support the need for hygienic documentation and traceability in the plant as certification such as EHEDG, 3-A or (EC)1935/2004 are available among other relevant certificates and manufacturing declarations

Cerabar PMP23: Part of a strong team for standard applications - Liquiphant, Liquipoint, Cerabar, Ceraphant

Pressure measuring principle

Spesifikasiyalar

Accuracy
0.3%
Process temperature
-10…+100°C (+14…+212°F) 135°C for 1h (275°F for 1h)
Pressure measuring range
400 mbar…+40 bar (6...+600psi)
Measuring cell
+400 mbar…+40 bar (+6 psi...+600 psi)
Measuring principle
Absolute and gauge pressure
Characteristic
Cost-effective pressure transducer, piezoresistive sensor with metallic measuring diaphragm for hygienic applications
Supply voltage
10…30 VDC
Reference Accuracy
0.3 %
Long term stability
0.2 % of URL/year
Process temperature
-10 °C…+100 °C (+14 °F…+212 °F) +135 °C for 1 h (+275 °F for 1 h)
Ambient temperature
-40 °C…+85 °C (-40 °F…+185 °F)
Measuring cell
+400 mbar…+40 bar (+6 psi...+600 psi)
Max. overpressure limit
160 bar (2400 psi)
Process connection
Threads: G1, M24
Process connection hygienic
DIN11851, Clamp, SMS, Varivent, Universal adapter
Communication
4...20 mA IO- Link
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, NEPSI, UK Ex
Design approvals
EN 10204-3.1Final inspection report Cleaned from oil + grease Surface roughness measurement
Hygienic approvals
3A, EHEDG EG1935/ 2004
Measuring principle
Absolute and gauge pressure
Characteristic / Application
Cost-effective pressure transducer, piezoresistive sensor with metallic measuring diaphragm for hygienic applications
Supply / Communication
10…30 VDC
Accuracy
0.3%
Long term stability
0.2% of URL/year
Ambient temperature
-40…+85°C (-40…+185°F)
Process temperature
-10…+100°C (+14…+212°F) 135°C for 1h (275°F for 1h)
Process pressure / max. overpressure limit
160 bar (2400 psi)
Pressure measuring range
400 mbar…+40 bar (6...+600psi)
Process connection
Thread: G1, M24
Process connection hygienic
DIN11851, Clamp, SMS, Varivent, Universal adapter
Communication
4...20 mA IO- Link
Certificates / Approvals
ATEX, FM, CSA, IEC Ex, NEPSI, UK Ex
Design approvals
EN 10204-3.1 Final inspection report Cleaned from oil + grease Surface roughness measurement
Hygienic approvals
3A, EHEDG EG1935/ 2004