Cerabar PMC71B - pressure transmitter

Cerabar PMC71B - pressure transmitter

Kateqoriya:Pressure
Məlumat

Məlumat

Smart pressure transmitter which detects process anomalies like changes in the loop characteristics

Stainless steel version

High temperature version

Pressure measuring range: up to 40 bar (600 psi)

Fully vacuum resistant up to +150°C (302°F) process temperature

Accuracy: up to +/- 0.025%

With Heartbeat Technology you are able to verify the health of the device while the process is running.

Simple indication of device status - display changes from green to red when diagnostic messages occur

Reduce systematic failures - error free SIL commissioning and instrument guided proof testing

Wireless control of the device in hard to reach process areas with the SmartBlue App

Spesifikasiyalar

Accuracy
Standard: up to 0.05 % Platinum: up to 0.025 %
Process temperature
-40°C...+150°C (-40°F...+302°F)
Pressure measuring range
100 mbar...40 bar (1.5 psi...600 psi)
Main wetted parts
Ceraphire ceramic FKM, EPDM, HNBR, Perlast, Kalrez, Chemraz
Material process membrane
Ceramic
Measuring cell
100 mbar....40 bar (1.5 psi...600 psi)
Measuring principle
Absolute and gauge pressure
Characteristic
Premium accuracy pressure transmitter with dry ceramic cell. Intuitive and clear wizards for commissioning, proof tests and verification.
Supply voltage
Ex d, Ex e, non-Ex: 10.5...35V DC Ex i: 10.5...30V DC
Reference Accuracy
Standard: up to 0.05 % Platinum: up to 0.025 %
Long term stability
0.05 % of URL/ year 0.08 % of URL/ 5 years 0.10 % of URL/ 10 years
Process temperature
-40°C...+150°C (-40°F...+302°F)
Ambient temperature
-40°C...+85°C (-40°C...+185°F)
Measuring cell
100 mbar....40 bar (1.5 psi...600 psi)
Smallest calibratable span
5 mbar (0.075 psi)
Vacuum resistance
0 mbar abs.
Max. Turn down
100:1
Max. overpressure limit
60 bar (900 psi)
Process connection
Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2 Flange: DN25...DN80, NPS 1"...4"
Material process membrane
Ceramic
Material gasket
FKM, EPDM, HNBR, FFKM
Fill fluid
none, dry measuring cell
Material housing
Aluminium, 316L
Communication
4...20 mA HART PROFIBUS PA PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional)
Certificates / Approvals
ATEX, CSA, IECEx, JPN Ex, INMETRO, NEPSI, UK Ex
Safety approvals
SIL
Design approvals
EN10204-3.1
Drinking water approvals
NSF, KTW
Specialities
Heartbeat Technology, Bluetooth® Operation and maintenance SmartBlue App, LED Module, RFID TAG for easy identification, Plug and play functionalities, HistoROM
Measuring principle
Absolute and gauge pressure
Characteristic / Application
Premium accuracy pressure transmitter with dry ceramic cell. Intuitive and clear wizards for commissioning, proof tests and verification.
Specialities
Heartbeat Technology, Bluetooth® Operation and maintenance SmartBlue App, LED Module, RFID TAG for easy identification, Plug and play functionalities, HistoROM
Supply / Communication
Ex d, Ex e, non-Ex:: 10.5...35V DC Ex i: 10.5...30V DC
Accuracy
Standard: up to 0.05 % Platinum: up to 0.025 %
Long term stability
0.05 % of URL/ year 0.08 % of URL/ 5 years 0.10 % of URL/ 10 years
Ambient temperature
-40°C...+85°C (-40°F...+185°F)
Process temperature
-40°C...+150°C (-40°F...+302°F)
Process pressure / max. overpressure limit
60 bar (900 psi)
Pressure measuring range
100 mbar...40 bar (1.5 psi...600 psi)
Main wetted parts
Ceraphire ceramic FKM, EPDM, HNBR, Perlast, Kalrez, Chemraz
Process connection
Thread: G1/2...G2, R1/2, MNPT1/2...MNPT2, FNPT1/2 Flange: DN25...DN80, NPS 1"...4"
Max. measurement distance
400 m (1312 ft) H2O
Communication
4...20 mA HART PROFIBUS PA PROFINET with Ethernet-APL Bluetooth® wireless technology and app (optional)
Certificates / Approvals
ATEX, IEC Ex, CSA C/US, NEPSI
Safety approvals
SIL
Design approvals
EN 10204-3.1
Drinking water approvals
NSF, KTW
Metrological approvals and certificates
MID
Options
Touch control display
Application limits
Measuring cell: ceramics If pressurized, possibly use differential pressure measurement with two pressure transmitters (electronic dp). Observe ratio head pressure : hydrostatic pressure