Cubemass DCI Coriolis flowmeter

Cubemass DCI Coriolis flowmeter

Kateqoriya:Flow measurement
Məlumat

Məlumat

Compact sensor for smallest quantities with seamless system integration

Cubemass DCI - The Coriolis flowmeter with backlit display and operation via touch control for measuring smallest quantities of liquids and gases

Measuring principle operates independently of physical fluid properties such as viscosity or density

Measuring accurately smallest quantities of liquids and gases

Device properties

Nominal diameter: DN 1 to 6 (1/24 to 1/4")

Process pressure up to 400 bar (5800 psi)

Medium temperature up to +200 °C (+392 °F)

Device as compact or remote version

Flexible outputs

Modbus RS485

Space-saving installation – compact single-tube design

Fewer process measuring points – multivariable measurement (flow, density, temperature)

Suitable for skids – lightweight sensor

High flexibility in system integration – wide range of communication interfaces

Fast commissioning – pre-configured devices

Automatic recovery of data for servicing

The Coriolis Flow Measuring Principle

Spesifikasiyalar

Max. measurement error
Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm3
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Wetted materials
Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L)
Measuring principle
Coriolis
Product headline
Compact sensor for smallest quantities with seamless system integration. Measuring accurately smallest quantities of liquids and gases.
Sensor features
Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
Transmitter features
High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Device as compact or remote version. Flexible outputs. Modbus RS485.
Nominal diameter range
DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
Wetted materials
Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error
Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm3
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
Powder‐coated die‐cast aluminium
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
Outputs
4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive), phase‐shifted pulse Relay
Inputs
1 modular input: status
Digital communication
HART, Modbus RS485
Power supply
DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals
ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL CRN
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Material certificates
3.1 material
Measuring principle
Coriolis
Product headline
Compact sensor for smallest quantities with seamless system integration. Measuring accurately smallest quantities of liquids and gases.
Sensor features
Space-saving installation – compact single-tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Suitable for skids – lightweight sensor. Nominal diameter: DN 1 to 6 (¹⁄₂₄ to ¹⁄₄"). Process pressure up to 400 bar (5800 psi). Medium temperature up to +200 °C (+392 °F).
Transmitter features
High flexibility in system integration – wide range of communication interfaces. Fast commissioning – pre-configured devices. Automatic recovery of data for servicing. Device as compact or remote version. Flexible outputs. Modbus RS485.
Nominal diameter range
DN 1 to 6 (¹⁄₂₄ to ¹⁄₄")
Wetted materials
Measuring tube: 1.4539 (904L) Connection: 1.4539 (904L); 1.4404 (316/316L)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error
Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm3
Measuring range
0 to 1000 kg/h (0 to 37 lb/min)
Max. process pressure
PN 40, Class 300, 10K, 400 bar (5800 psi)
Medium temperature range
–50 to +200 °C (–58 to +392 °F)
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
Powder‐coated die‐cast aluminium
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
Outputs
4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive), phase‐shifted pulse Relay
Inputs
1 modular input: status
Digital communication
HART, Modbus RS485
Power supply
DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals
ATEX, IECEx, NEC/CEC, NEPSI
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL CRN