
Sənədlər
Spesifikasiyalar
Product headline
Calculated volume or mass flow measurement. dp primary element (Pitot).
Averaging pitot tube with 12mm diamond profile.
Sensor features
Insertion system.
Pipe size DN40...125 ; 1-1/2...5".
Retractable version available.
Bidirectional measurement.
Compact or remote design.
Deltabar S/M differential pressure transmitter.
Nominal diameter range
DN 40...125
1 -1/2" ... 5"
Max. measurement error
typically 1% of calculated volume or mass.
Measuring range
1.0 ... 600m3/h
Max. process pressure
PN6 ... 250
Cl.300 ... 1500
Medium temperature range
Compact version:
-200°C ... 200°C
-328°F ... 392°F
Remote version:
-200°C ... 1000°C
-328°F ... 1832°F
Degree of protection
Transmitter (Deltabar):
IP67
NEMA6P
Display/Operation
Transmitter (Deltabar):
4-line display
3 push buttons
Quick setup
HistoROM
Outputs
Transmitter (Deltabar):
4 ... 20 mA
Digital communication
Transmitter (Deltabar):
HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals
Transmitter (Deltabar):
ATEX
FM
CSA
IEC
TIIS
NEPSI
Product headline
Calculated volume or mass flow measurement. dp primary element (Pitot).
Averaging pitot tube with 12mm diamond profile.
Sensor features
Insertion system.
Pipe size DN40...125 ; 1-1/2...5".
Retractable version available.
Bidirectional measurement.
Compact or remote design.
Deltabar S/M differential pressure transmitter.
Nominal diameter range
DN 40...125
1 -1/2" ... 5"
Max. measurement error
typically 1% of calculated volume or mass.
Uncertainty of primary element excluding uncertainty of density or compensation.
Measuring range
25 ... 10'000m3/h
Max. process pressure
PN6 ... 250
Cl.300 ... 1500
Medium temperature range
Compact version:
-200°C ... 200°C
-328°F ... 392°F
Remote version:
-200°C ... 1000°C
-328°F ... 1832°F
Degree of protection
Transmitter (Deltabar):
IP67
NEMA6P
Display/Operation
Transmitter (Deltabar):
4-line display
3 push buttons
Quick setup
HistoROM
Outputs
Transmitter (Deltabar):
4 ... 20 mA
Digital communication
Transmitter (Deltabar):
HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals
Transmitter (Deltabar):
ATEX
FM
CSA
IEC
TIIS
NEPSI
Product headline
Calculated volume or mass flow measurement. dp primary element (Pitot).
Averaging pitot tube with 12mm diamond profile.
Sensor features
Insertion system.
Pipe size DN40...125 ; 1-1/2...5".
Retractable version available.
Bidirectional measurement.
Compact or remote design.
Deltabar S/M differential pressure transmitter.
Nominal diameter range
DN 40...125
1 -1/2" ... 5"
Max. measurement error
typically 1% of calculated volume or mass.
Uncertainty of primary element excluding uncertainty of density or compensation.
Measuring range
25 ... 6'500 m3/h
125 ... 33'000 kg/h at 10bar/230°C
Max. process pressure
PN6 ... 250
Cl.300 ... 1500
Medium temperature range
Compact version:
-200°C ... 200°C
-328°F ... 392°F
Remote version:
-200°C ... 1000°C
-328°F ... 1832°F
Degree of protection
Transmitter (Deltabar):
IP67
NEMA6P
Display/Operation
Transmitter (Deltabar):
4-line display
3 push buttons
Quick setup
HistoROM
Outputs
Transmitter (Deltabar):
4 ... 20 mA
Digital communication
Transmitter (Deltabar):
HART
PROFIBUS PA
FOUNDATION Fieldbus
Hazardous area approvals
Transmitter (Deltabar):
ATEX
FM
CSA
IEC
TIIS
NEPSI
