FLOWSIC600 DRU-S ultrasonic flowmeter

FLOWSIC600 DRU-S ultrasonic flowmeter

Kateqoriya:Flow measurement
Məlumat

Məlumat

Simple and robust upstream gas flow measurement

Natural gas measurement in gas production

Associated gas measurement in oil production

Wellhead and gaslift measurement

Raw natural gas measurement at gas treatment plants (VRU, VRT, dehydration units, etc.)

Device properties:

Designed for wet gas applications

No pressure drop

High turndown ratio ≥ 100:1

Operates from atmospheric pressure

New diagnostic feature – Liquid indication

Plug & play connection to Monitoring Box for remote diagnostics

Highly reliable – continuous gas measurement even in wet and dirty process conditions

Low initial investment - accurate measurement without expensive flow calibration

Elimination of scheduled maintenance with real-time remote diagnostics

Advanced process monitoring capability with unique liquid detection

Long life - wet gas resistant titanium ultrasonic sensors

Spesifikasiyalar

Measured variables
Volumetric flow a. c., volume a. c., gas velocity, sound velocity
Measuring Medium
Natural gas, Associated gas , Raw Natural gas
Nominal pipe size
2" / 3" / 4"
Measuring principle
Ultrasonic transit time difference measurement
Measured variables
Volumetric flow a. c., volume a. c., gas velocity, sound velocity
Measuring Medium
Natural gas, Associated gas , Raw Natural gas
Repeatability
± 0.2 % of the measured value (between Qt and Qmax depending on the installation requirements)
Accuracy
Error limits Qt ... Qmax ± 2 %
Medium temperature range
–40 °C ... +100 °C / –40 °F … 212 °F
Operating pressure range
0 bar(g) … 16 bar(g) / 0 psi(g) … 230 psi(g) for ANSI CL150 0 bar(g) … 100 bar(g) / 0 psi(g) … 1450 psi(g) for ANSI CL600
Nominal pipe size
2" / 3" / 4"
Hazardous area approvals
IECEx: Gb/Ga Ex db eb ib [ia Ga] IIA T4 Ultrasonic transducer, intrinsically safe ATEX: II 1/2 (1) G Ex ia/ db eb ia [ia Ga] IIA T4 …T1 Ga/Gb Ultrasonic transducer, intrinsically safe NEC/CEC (US/CA): Class I, Division 1, Group D T4 Class I, Division 2, Group D T4 Ultrasonic transducers intrinsically safe
Digital Outputs
2 DO and 1 FO: 30 V, 10 mA Passive, galvanically isolated, open collector, fmax = 6 kHz (scalable)
Digital communication
RTU RS-485 (2x, for configuration, data output and diagnostics) ASCII RS-485 (2x, for configuration, data output and diagnostics)