Guided radar measurement Time-of-Flight Levelflex FMP53

Guided radar measurement Time-of-Flight Levelflex FMP53

Kateqoriya:Level
Məlumat

Məlumat

For the highest hygiene requirements in the food and life sciences industry

Version with rod probe.

Process connections: For hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO, Varivent N, SMS)

Temperature: -20 to +150°C (-4 to +302°F)

Pressure: -1 to +16bar (-14.5 to +232psi)

Maximum measuring range: Rod 6m (20ft)

Accuracy: ±2mm (0.12")

International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, 5-point linearity protocol

Reliable measurement even for changing product and process conditions

HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

Highest reliability due to new Multi-Echo Tracking evaluation

Hardware and software developed according to IEC 61508 up to SIL3

Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle

Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)

World's easiest proof test for SIL and WHG saves time and costs

Time-of-Flight measuring principle

Commissioning movie for Levelflex FMP5x guided radar and Micropilot FMR5x free space radar

Unique HistoROM data management concept for safe level measurement

Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking

Multi-Echo Tracking with Tank Trace marks and traces all echoes signals, not only the level signal - guaranteeing safe measurement at any time

Spesifikasiyalar

Accuracy
Rod probe:+/- 2 mm (0.08 in)
Process temperature
-20...+150 °C (-4...+302 °F)
Process pressure / max. overpressure limit
Vacuum...16 bar (Vacuum...232 psi)
Max. measurement distance
Rod: 6 m (20 ft) Min DK>1.6
Main wetted parts
Rod probe: 304, 304L, 316L, PEEK
Measuring principle
Guided radar
Characteristic / Application
Premium device. Hygiene Rod probe, ASME BPE + USP Class VI compliant, Integrated data memory, Factory precalibrated, Reliable measuring: in case of moved surface + foam, for changing medias, for filling via spray head.
Specialities
Heartbeat Technology, Bluetooth® commissioning, Operation and maintenance SmartBlue App, HistoROM, RFID TAG for easy identification
Supply / Communication
2-wire (HART / PROFIBUS PA/ FOUNDATION Fieldbus) 4-wire (HART) Bluetooth® wireless technology and App (optional)
Accuracy
Rod probe:+/- 2 mm (0.08 in)
Ambient temperature
-20...+80 °C (-4...+176 °F)
Process temperature
-20...+150 °C (-4...+302 °F)
Process pressure / max. overpressure limit
Vacuum...16 bar (Vacuum...232 psi)
Main wetted parts
Rod probe: 304, 304L, 316L, PEEK
Process connection
Thread: M24
Process connection hygienic
Tri-Clamp DIN11851 DIN11864-1 NEUMO Varivent N SMS
Sensor length
Rod probe: 6 m (20 ft)
Max. measurement distance
Rod: 6 m (20 ft) Min DK>1.6
Communication
4...20 mA HART PROFIBUS PA FOUNDATION Fieldbus Bluetooth® wireless technology
Certificates / Approvals
ATEX, FM, CSA C/US, IEC Ex, INMETRO, NEPSI, KC, EAC, UK Ex
Safety approvals
Overfill protection WHG SIL
Design approvals
EN 10204-3.1
Hygienic approvals
3A, EHEDG CoC ASME-BPE
Options
Sensor remote with 3 m/9 ft or 6 m/18 ft cable, Weld-in adpater, Remote operation via SmartBlue App using Bluetooth®
Application limits
Application limits