Hydrostatic Level measurement Waterpilot FMX11

Hydrostatic Level measurement Waterpilot FMX11

Kateqoriya:Pressure
Məlumat

Məlumat

Simple and reliable level probe for freshwater applications

Temperature: –10 to +70°C (14 to 158°F)

Measuring range: 0 to 2bar / 20m H20 (0 to 30psi / 67ft H 2 O)

Cable length: 6 to 30m

Accuracy: up to ±0.35%

Drinking water approvals: ACS, KTW, NSF61, DVGW

Certifications: cULus

Simple and reliable transmitter for various drinking water applications

Easy installation, commissioning and operation

Orderable with flexible measuring ranges and cable lengths tailored to fit your application

Robust construction for durable long-term services

Suitable for surface water monitoring in rivers and lakes as well as level monitoring for drinking water production, e.g. in water towers, dams, gauging stations

Compact size d=22mm (0.87”), makes this an excellent choice for applications in bore holes and small diameter stilling wells.

Simple specification and ordering

Pressure measuring principle

Spesifikasiyalar

Accuracy
pn ≥ 400mbar: 0.35 % pn < 400mbar: 0.50 %
Process temperature
-10°C...+70°C (+14°F...+158°F)
Pressure measuring range
200 mbar...2 bar (3 psi...29 psi)
Process pressure / max. overpressure limit
10 bar (145 psi)
Main wetted parts
316L
Max. measurement distance
20 m H2O (66 ft H2O)
Material process membrane
Metal
Measuring cell
200 mbar...2 bar (3 psi...29 psi)
Measuring principle
Hydrostatic pressure
Characteristic
Compact probe with metallic cell for hydrostatic level measurement in fresh water, ground water and potable water storage.
Supply voltage
8...28 VDC
Reference Accuracy
pn ≥ 400mbar: 0.35 % pn < 400mbar: 0.50 %
Long term stability
0.1 % of URL/year
Process temperature
-10°C...+70°C (+14°F...+158°F)
Ambient temperature
-10°C...+70°C (+14°F...+158°F)
Measuring cell
200 mbar...2 bar (3 psi...29 psi)
Process connection
Suspension clamp Cable mounting screws
Material process membrane
Metal
Communication
4...20 mA
Drinking water approvals
NSF, KTW, ACS
Measuring principle
Hydrostatic
Characteristic / Application
Compact probe with metallic cell for hydrostatic level measurement in fresh water, ground water and potable water storage.
Supply / Communication
8...28 VDC
Accuracy
pn ≥ 400mbar: 0.35 % pn < 400mbar: 0.50 %
Long term stability
0.1% of URL/year
Ambient temperature
-10°C...+70°C (+14°F...+158°F)
Process temperature
-10°C...+70°C (+14°F...+158°F)
Process pressure / max. overpressure limit
10 bar (145 psi)
Pressure measuring range
200 mbar...2 bar (3 psi...29 psi)
Main wetted parts
316L
Process connection
Suspension clamp Cable mounting screws
Max. measurement distance
20 m H2O (66 ft H2O)
Communication
4...20 mA
Drinking water approvals
NSF, KTW, ACS