Məlumat
Məlumat
Modular assembly for water, wastewater and utilities
Flexdip CYA112 is a modular assembly for all measurements in open basins, channels and tanks in:
Wastewater treatment plants
Water works
Utilities of all industries
It forms a perfect team with the Flexdip CYH112 holder for simple sensor isolation.
The Flexdip team is suitable for all parameters, such as:
pH/ORP
Conductivity
Oxygen
Turbidity
Sludge level
Disinfection
UV photometry
Nutrients
The modular system allows an optimum configuration for every measuring place
Fast installation and exchange of Memosens sensors with contactless plug-in head
Twist-free installation of fixed-cable sensors
Easy to install and to maintain
Sənədlər
Spesifikasiyalar
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
Potentiometric
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
Sensor ORP / Redox
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
Conductive
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Tauchrohr Durchmesser: 40 mm (1.57 Zoll)
Länge: 600, 1200, 1800 und 2400 mm
(23.6, 47.2, 70.9 und 94.5 Zoll)
Process temperature
0 ... 60 °C (32 ... 140 °F)
Measuring principle
Amperometric oxygen measurement
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
Total chlorine
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
Single beam scattered light
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels
Installation
CYA112 is a modular assembly system for sensors in open basins, channels and tanks
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Material
Immersion pipe, connection angle, welded threads: stainless steel 1.4404
Sensor adaption, quick fastener, multifunctional clamp ring: POM - GF
O-rings: EPDM
Dimension
Immersion pipe diameter: 40 mm (1.57 inch)
Length: 600, 1200, 1800 and 2400 mm
(23.6, 47.2, 70.9 and 94.5 inch)
Process temperature
0 to 60 °C (32 to 140 °F)
Measuring principle
UV photometric
Characteristic
Simple and easy installation
Universal and flexible
Design
Versions in stainless steel or PVC
Process temperature
0 to 60 °C (32 to 140 °F)
Application
Water treatment, wastewater treatment, plant design, open channels, basins, open tanks and process vats, fluctuating water levels