MCS200HW emission monitoring solution

MCS200HW emission monitoring solution

Kateqoriya:Optical analysis
Məlumat

Məlumat

Proven measurement technology for flue gas monitoring

Emission monitoring for waste incineration plants as well as power plants and plants with co-incineration, e.g. cement plants

Measurement of nitrogen oxides in nitric acid plants

Device properties:

Measurement of up to 10 IR components plus O 2 and TOC

Wear-free gas distribution through ejector pumps

Reference point monitoring with internal calibration cells

Web server for platform-independent device control

Use of dry test gases for HCl and NH3

Classification for ATEX Zone 2, IIC T3 gb

Only one analyzer necessary for simultaneous monitoring of up to 12 gas components

Convenient, task-oriented operation

Remote access without additional software

High availability due to certified internal third-party monitoring (QAL3) without test gases

Data transmission possible via just one interface

Use in explosion-hazardous areas thanks to rugged, pressurized housing

Spesifikasiyalar

Measured variables
CH4, CO, CO2, Corg, HCl, H2O, NH3, NO, NO2, N2O, O2, SO2
Ambient temperature range
+5 °C ... +50 °C
Process temperature
≤ +550 °C
Measuring principle
Interference filter correlation, Gas filter correlation
Measured variables
CH4, CO, CO2, Corg, HCl, H2O, NH3, NO, NO2, N2O, O2, SO2
Performance-tested measurands
CH4, CO, CO2, Corg, HCl, H2O, NH3, NO, NO2, N2O, O2, SO2
Certified measuring ranges
CH4: 0 ... 50 mg/m³ / 0 ... 500 mg/m³ CO: 0 ... 30 mg/m³ / 0 ... 10,000 mg/m³ CO2: 0 ... 25% by vol. Corg: 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 150 mg/m³ / 0 ... 500 mg/m³ HCl: 0 ... 15 mg/m³ / 0 ... 3,000 mg/m³ H2O: 0 ... 40% by vol. NH3: 0 ... 7 mg/m³ / 0 ... 500 mg/m³ NO: 0 ... 50 mg/m³ / 0 ... 2,500 mg/m³ NO2: 0 ... 50 mg/m³ / 0 ... 500 mg/m³ N2O: 0 ... 45 mg/m³ / 0 ... 2,000 mg/m³ O2: 0 ... 25% by vol. SO2: 0 ... 75 mg/m³ / 0 ... 2,500 mg/m³
Process temperature
≤ +550 °C
Process pressure
850 hPa ... 1,100 hPa
Ambient temperature range
+5 °C ... +50 °C
Ambient humidity
≤ 90 % Relative humidity; non-condensing
Conformities
Approved for plants requiring approval 2000/76/EC (17. BImSchV) 2001/80/EC (13. BImSchV) 27. BImSchV EN 15267 EN 14181
Hazardous area approvals
MCS200HW Ex: ATEX: II 3G Ex dc ec ic [ic] mc nC pzc IIC T3 Gc Analyzer cabinet II 3G Ex ec IIC T3 Gc Gas sampling unit I 2G Ex eb IIC T Gb Sample gas line IECEx: on request.
Degree of protection
MCS200HW: IP54 MCS200HW Ex: IP65
Product safety
CE