Sənədlər
Spesifikasiyalar
Product headline
The easy‐to‐clean flowmeter with self‐drainable singletube system and an ultra‐compact transmitter. Dedicated for applications requiring optimal cleanability under hygienic conditions.
Sensor features
Increased process safety – easy cleanable and fully self‐drainable tube design. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Large range of hygienic process connections. 3-A and EHEDG conform.
Transmitter features
Space‐saving transmitter – full functionality on smallest footprint. Time‐saving local operation without additional software and hardware – integrated web server. Integrated verification – Heartbeat Technology. Robust, ultra‐compact transmitter housing. High ingress protection: IP69K.
Nominal diameter range
DN 8 to 50 (⅜ to 2")
Wetted materials
Measuring tube: 1.4435 (316L)
Connection: 1.4435 (316L); 1.4404 (316/316L)
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration
Max. measurement error
Mass flow (liquid): ±0.1 %
Volume flow (liquid): ±0.1 %
Mass flow (gas): ±0.5 %
Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 70 000 kg/h (0 to 2570 lb/min)
Max. process pressure
PN 40, Class 150, 20K
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)
Sensor housing material
1.4301 (304), corrosion resistant
Transmitter housing material
Compact: AlSi10Mg, coated
Compact/ultra‐compact: 1.4301 (304), 1.4404 (316L)
Degree of protection
Standard: IP66/67, type 4X enclosure
Option: IP69K
Display/Operation
4‐line backlit display available (no local operation)
Configuration via web browser and operating tools possible
Outputs
4‐20 mA HART (active)
Pulse/frequency/switch output (passive)
Inputs
None
Digital communication
HART, Modbus RS485, EtherNet/IP, PROFIBUS DP, PROFINET
Power supply
DC 20 to 30 V
Hazardous area approvals
ATEX, IECEx, cCSAus, INMETRO, NEPSI, TIIS
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Heartbeat Technology complies with the requirements for traceable verification according to ISO 9001:2008 – Section 7.6 a (TÜV SÜD Attestation)
PED, CRN
3-A, EHEDG