Proline Prosonic Flow W 400 ultrasonic clamp-on flowmeter

Proline Prosonic Flow W 400 ultrasonic clamp-on flowmeter

Kateqoriya:Flow measurement
Məlumat

Məlumat

Reliable, flexible, zero maintenance – noninvasive flow measurement, consistently accurate, even in limited spaces

Ultrasonic clamp-on flowmeter Proline Prosonic Flow W 400 – noninvasive and easy to install – no process interruption – maintenance-free operation

When space is limited: Ultrasonic clamp-on flowmeter with FlowDC function for consistently high performance even at only 2 x DN inlet runs

Ultrasonic flow measurement in an energy plant – maintenance-free clamp-on sensors on a DN 2000 pipe

Consistently high measurement performance in spite of disturbed flow profile – Prosonic Flow W 400 with FlowDC

Special coupling pads make this ultrasonic clamp-on system maintenance-free during the entire product life cycle.

Heartbeat Technology provides continuous process transparency with its diagnostic, verification and monitoring functions. This way, build-up can be detected before it affects operation.

Flexible mounting – FlowDC reduces inlet runs to a minimum

Reliable measurement performance – proven sensors in combination with maintenance-free mounting system deliver long-term stable signals

Low capital investment – cost-effectiveness increases with the pipe diameter (up to DN 4000/160")

User-friendly operation – the web server offers full remote access, while the device’s display offers convenient on-site interaction

Transparent process insights – Heartbeat Technology with its integrated diagnostics, verification and monitoring functions enable compliance and process safety at all times

How to install an Endress+Hauser ultraonic clamp-on flowmeter

How FlowDC function reduces inlet runs to a minimum

Straightforward application of FlowDC in practice

The ultrasonic flow measuring principle

Spesifikasiyalar

Max. measurement error
Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to 200 ±2% o.r. above DN200
Measuring range
0 to 15 m/s (0 to 50 ft/s)
Medium temperature range
–40 to +130 °C (–40 to +266 °F)
Max. process pressure
N/A
Measuring principle
Ultrasonic flow
Product headline
Clamp-on meter with Heartbeat Technology and web server for the water and wastewater industry. Short inlet run thanks to FlowDC. Bidirectional measurement for water and wastewater as well as process water and hydropower plants.
Sensor features
Low capital investment – cost-effectiveness increases with pipe diameter (up to DN 2000/80"). Long-term stable signal – maintenance-free permanent mounting from outside with coupling pads. Reliable measurement on various pipe materials – sensor for GRP and plastic pipes available. Mounting without process interruption. Wide nominal diameter range: DN 15 to 4000 (½ to 160"). Medium temperature up to +130 °C (+266 °F).
Transmitter features
Safe operation – no need to open the device due to display with touch control, background lighting. Full remote access – web server. Integrated diagnostics, verification and monitoring – Heartbeat Technology. Transmitter housing made of durable polycarbonate or aluminium. Remote version for wall mounting. Integrated data logger: measured values monitoring.
Nominal diameter range
DN15 to 4000 (1/2 to 160")
Sensor materials
Clamp on system: Sensor holder 1.4301 (304), 1.4404 (316L) Sensor housing 1.4301 (304), 1.4404 (316L) Strapping bands 1.4301 (304), 1.4404 (316L)
Measured variables
Volume flow, Flow velocity, Sound velocity
Max. measurement error
Volume flow: ±3% o.r. for DN15 ±2% o.r. for DN25 to 200 ±2% o.r. above DN200
Measuring range
0 to 15 m/s (0 to 50 ft/s)
Max. process pressure
N/A
Medium temperature range
–40 to +130 °C (–40 to +266 °F)
Ambient temperature range
Sensor DN 15 to 65: -40 to 130°C Sensor DN 50 to 4000: -40 to 130°C
Sensor housing material
N/A
Transmitter housing material
Wall-mounted housing Polycarbonat; AlSi10Mg, coated
Degree of protection
Transmitter: IP66/67, Type 4X enclosure Sensor: IP66/67, Type 4X enclosure, IP68, Type 6P enclosure (optional)
Display/Operation
4‐line backlit display with touch control (operation from outside) Configuration via local display, web browser and operating tools possible
Outputs
3 ouputs: 4‐20 mA/4‐20 mA HART (active) Pulse/frequency/switch output (passive) Pulse/frequency/switch output (passive) Modbus RS485
Inputs
Status input
Digital communication
HART
Power supply
AC 100 to 240 V / AC/DC 24 V
Approvals
cCSAus
Other approvals and certificates
Other approvals and certificates
Product safety
CE, C-tick marking, EAC-marking
Metrological approvals and certificates
Flowmeter verification for all frequencies except 0.3 MHz, reference line size: 5 MHz DN 50, all other frequencies DN 100 Verification performed on accredited calibration facilities (acc. to ISO/IEC 17025) Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a
Marine approvals and certificates
Marine approvals and certificates