Promass 83I

Promass 83I

Kateqoriya:Flow measurement

Spesifikasiyalar

Measuring principle
Coriolis
Product headline
Combines in‐line viscosity and flow measurement with extended transmitter functionality. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Sensor features
Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB technology.
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
Nominal diameter range
DN 8 to 80 (⅜ to 3")
Wetted materials
Measuring tube: Titanium grade 9 Connection: Titanium grade 2
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
Max. measurement error
Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
Outputs
4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay
Inputs
2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive)
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supply
DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL PED, CRN 3-A
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material
Hygienic approvals and certificates
3-A, EHEDG
Measuring principle
Coriolis
Product headline
Combines in‐line viscosity and flow measurement with extended transmitter functionality. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Sensor features
Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB technology.
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
Nominal diameter range
DN 8 to 80 (⅜ to 3")
Wetted materials
Measuring tube: Titanium grade 9 Connection: Titanium grade 2
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
Max. measurement error
Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
Outputs
4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay
Inputs
2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive)
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supply
DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL PED, CRN 3-A
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material
Hygienic approvals and certificates
3-A, EHEDG
Measuring principle
Coriolis
Characteristic / Application
Balanced single-tube system, "Fit-and-Forget" installation Design: Easy to clean, hygienic, careful handling of the medium - chemically resistant material
Ambient temperature
-20...+65°C (-4...+140°F)
Process temperature
-50...+150°C (-58...+302°F)
Process pressure
PN 16...100 Cl 150...600 JIS 10...63K
Wetted parts
Titan
Output
4...20mA Pulse/Frequency (10KHz), active/passiveRelays/Status
Certificates / Approvals
ATEX FM CSA
Measuring principle
Coriolis
Product headline
Combines in‐line viscosity and flow measurement with extended transmitter functionality. Measuring liquids and gases in applications requiring low pressure loss and gentle fluid treatment.
Sensor features
Energy‐saving – full bore design enables minimal pressure loss. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Straight, easy cleanable single‐tube system. TMB technology.
Transmitter features
Quality – software for filling & dosing, density & concentration, advanced diagnostics. Flexible data transfer options – numerous communication types. Automatic recovery of data for servicing. 4‐ line backlit display with touch control. Device in compact or remote version.
Nominal diameter range
DN 8 to 80 (⅜ to 3")
Wetted materials
Measuring tube: Titanium grade 9 Connection: Titanium grade 2
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration, viscosity
Max. measurement error
Mass flow (liquid): ±0.1 % Volume flow (liquid): ±0.1 % Mass flow (gas): ±0.5 % Density (liquid): ±0.0005 g/cm³
Measuring range
0 to 180 000 kg/h (0 to 6600 lb/min)
Max. process pressure
PN 100, Class 600, 63K
Medium temperature range
–50 to +150 °C (–58 to +302 °F)
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F) Option: –40 to +60 °C (–40 to +140 °F)
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
Transmitter housing material
Powder‐coated die‐cast aluminium 1.4301 (304), sheet CF3M (316L), cast
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
Display/Operation
4‐line backlit display with touch control (operation from outside) Configuration via local display and operating tools possible
Outputs
4 modular outputs: 0‐20 mA (active)/4‐20 mA (active/passive) Pulse/frequency/switch output (passive) Relay
Inputs
2 modular inputs: Status 0‐20 mA (active)/4‐20 mA (active/passive)
Digital communication
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus, Modbus RS485, EtherNet/IP
Power supply
DC 16 to 62 V AC 85 to 260 V (45 to 65 Hz) AC 20 to 55 V (45 to 65 Hz)
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
Product safety
CE, C-tick, EAC marking
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
Pressure approvals and certificates
PED, CRN
Material certificates
3.1 material
Hygienic approvals and certificates
3-A, EHEDG
Measuring principle
Coriolis
Main features
Balanced singe-tube system, "Fit-and-Forget" installation, viscosity measurement Design: Easy to clean, hygienic, careful handling of the medium
Diameter
DN 8...80 5/16"...3"
Measuring range
0...180'000 kg/h 0... 20'000 cP (viscosity)
Process temperature
-50...+150°C (-58...+302°F)
Pressure range
PN 16...100 CI 150...600 JIS 10...63K
Measurement error
Mass flow: +-0.1% Volume flow: +-0.5% Viscosity: ± 5% ± 0.5 mPa•s (Newtonian fluids) Density: +- 0.004g/cc
Display/Operation
Four line backlit Touch control
Inputs
Status Current input
Outputs
0/4...20mA Pulse Frequency (10KHz), active/passive Relays/Status
Communication
HART PROFIBUS PA Profibus DP FOUNDATION Fieldbus
Ex-Approvals
ATEX FM CSA
Protection electronic
IP 67 NEMA 4x
Features
S-DAT, T-DAT, F-Chip Validation Quick Set-up 3 Totalizers Pulsating Flow Advanced diagnostics Batching Concentration measurement
Advantages
Balanced single-tube system. Dual mode for independent viscosity measurement. High vibration immunity. Easy and cost-effective mounting. Measurement is independent of fluid properties. Promass 83 with "Touch Control": Operation from outside without opening the house. Software pagackes may be updated for: - Dosage applications - Concentration measurement - Advanced diagnostics "Quick Setup" menus for straightforward commissioning in the field.