TMR35 Compact thermometer

TMR35 Compact thermometer

Kateqoriya:Temperature
Məlumat

Məlumat

Metric RTD 4-20 mA compact thermometer for hygienic applications

The TMR35 compact thermometers are used to measure temperatures from -50 °C to +150 °C (-58 °F to +302 °F), or up to +200 °C (+392 °F) with neck. The most common installation locations are tanks and pipes. TMR35 with process connections for hygienic applications.

Small, compact design made entirely of stainless steel

Extremely short response times

Highly accurate even with short insertion lengths

4-wire, Pt100 or PC-programmable transmitter with 4 to 20 mA output

Configuration and visualization with ReadWin ® 2000 PC operating software, which is free of charge

Breakdown information in event of sensor break or sensor short-circuit, adjustable as per NAMUR NE43

Hygienic compatible design with 3-A marking and EHEDG certification; Marine approval

Spesifikasiyalar

Accuracy
class A acc. to IEC 60751
Response time
t50 = 1 s t90 = 2 s
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
Operating temperature range
PT 100: -50 °C ...200 °C (-58 °F ...392 °F)
Max. immersion length on request
up to 600,00 mm (23,62'')
Measuring principle
Resistance Temperature Detector
Characteristic / Application
metric style compact temperature probe fast response time hygienic design hygienic process connection with or without neck
Thermowell / protection tube
without (not intended to be used with thermowell) to be used with thermowell incl. Tee-/elbow thermowell
Insert / probe
pipe version, isolated wires, not flexible
Outer diameter protection tube / Insert
3,0 mm (0,12'') 6,0 mm (0,24'')
Max. immersion length on request
up to 600,00 mm (23,62'')
Material protection tube/ thermowell
1.4404 (316L)
Process connection
hygienic: conical sealing system G1/2" (metal) clamp connections acc. to ISO 2852 / DIN 32676 screwed pipe joint acc. to DIN 11851 Varivent
Tip shape
straight
Surface roughness Ra
0,4 μm (16 μin.) 0,8 μm (32 μin.)
Operating temperature range
PT 100: -50 °C ...200 °C (-58 °F ...392 °F)
Max. process pressure (static)
at 20 °C: 100 bar (1.450 psi)
Accuracy
class A acc. to IEC 60751
Response time
t50 = 1 s t90 = 2 s
Integration head transmitter
no (4…20mA Signal)
Certification
3A Marine approval UL 3111-1